How do I set the overcurrent protection (OCP) in PAT-T series?

OCP is the protection that prevents a load from an excessive current. OCP is activated if the current exceeds an overcurrent set value to turn the output off.
To set OCP,
a) Press the OVP/OCP key.
The OVP/OCP LED lights and the OVP/OCP set value is shown on the panel.
b) Turn the CURRENT knob to set the OCP value.
c) In CF28 of the CONFIG setting, you can set whether to trip the breaker (turn the POWER switch off) when OCP is activated.
e) You can set whether to limit the output current that doesn’t exceed the OCP set value. Go to CF30 of the CONFIG setting to set to on, so that the output current cannot be set to more than 95% of the OCP set value.
For the details, read the user’s manual – chapter of Protection Functions and Alarms.
For more in-depth information, download the technical data from our website.