Why doesn’t PBZ series operate by inputting trigger signals via the TRIG IN contact?

The TRIG IN terminal of PBZ series doesn’t accept trigger signals from a contact or open collector signals.
Please apply a pulse voltage of 5 V for at least 1 µs (microsecond).
For the details, read the user’s manual – chapter of Specifications – Signal I/O.