| DC voltage | Rating *1 | -226 V to +226 V, -452 V to +452 V *2 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Setting range *1 | -227.5 V to +227.5 V, -455.0 V to +455.0 V | |||||||||
| Resolution | 0.1 V | |||||||||
| Accuracy *9 | ±(0.05 % of setting + 0.1 V) | |||||||||
| Maximum current *6 | 10 A / 5 A | 20 A / 10 A | 30 A / 15 A | 60 A / 30 A | 120 A / 60 A | 180 A / 90 A | 240 A / 120 A | 300 A / 150 A | 360 A / 180 A | |
| Power capacity | 1 kW | 2 kW | 3 kW | 6 kW | 12 kW | 18 kW | 24 kW | 30 kW | 36 kW | |
1 output L range, output H range
*2 Specification guaranteed voltage range is 1 V to 160 V/ 2 V to 320 V (AC) and 1.4 V to 226 V/ 2.8 V to 452 V (DC)
*3 At ambient temperature of 23 °C±5 °C.
*4 No load, output frequency 45 Hz to 65 Hz
*5 When the phase angle of 120° of each phase.
*6 For output phase voltage of 100 Vac to 160 Vac/ 200 Vac to 320 Vac and out-put voltage of 100 Vdc to 226 Vdc/ 200 Vdc to 452 Vdc, output current is reduced with output voltage.
When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. The output current is 70 % at 1 Hz.
*7 On the 500 Hz limit model, the frequency is limited to 1 Hz to 500.0 Hz for three-phase output.
*8 Within ±(0.4° + 2.5 μs×360°×fo×103). The following show the angles obtained by calculating the expression with the specified frequency, within ± 0.5° (at 60 Hz output), within ± 0.8° (at 400 Hz output)
*9 With no load at 23°C±5°C.
*10 When the output voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 1 kHz.
*11 Repeated output is possible when the crest factor is 4.
*12 125 Vac/ 250 Vac (output L range/ H range)
*13 Waveform bank 0, at 1 Hz to 500 Hz.