PFX2500_Specifications

Rated output

 PFX2512PFX2532
Number of outputs1 ch1 ch
Charging current range*10.000 A to 50.000 A0.000 A to 200.000 A
Charging voltage range*160 V range0.000 V to 60.000 V0.000 V to 60.000 V
6 V range0.000 V to 6.000 V0.000 V to 6.000 V
Discharge current range*10.000 A to 50.000 A0.000 A to 200.000 A
Discharge voltage range*1*260 V range0.000 V to 60.000 V0.000 V to 60.000 V
6 V range0.000 V to 6.000 V0.000 V to 6.000 V

Measurement accuracy

 PFX2512PFX2532
Static
Charge/ discharge
Current measurement
Range0.0000 A to 50.0000 A0.000 A to 200.000 A
Accuracy*3± (0.15 % of reading + 0.02 % of rating)± (0.2 % of reading + 0.1 % of rating)
Resolution0.1mA1mA
Voltage measurementRange60 V range-6.0000 V to 60.0000 V-6.0000 V to 60.0000 V
6 V range-1.0000 V to 6.0000 V-1.0000 V to 6.0000 V
Accuracy*360 V range± (0.05 % of reading + 0.02 % of rating)± (0.05 % of reading + 0.02 % of rating)
6 V range± (0.05 % of reading + 0.04 % of rating)± (0.05 % of reading + 0.04 % of rating)
Resolution*40.1mV0.1mV
Power measurementRange0.000 W to 3000.000 W0.0 W to 12000.0 W
AccuracySoftware calculation (voltage measurement × current measurement)
Resolution1mW100mW
Current Capacity calculationRange0.000 Ah to 2000.000 Ah0.000 Ah to 2000.000 Ah
AccuracyDepends on the current measurement accuracy and the time accuracy
Resolution1mAh1mAh
Time*5Accuracy*3*6±10 ppm (TYP values)±10 ppm (TYP values)

*1 Range might be different depending on power supply to be connected, model of electronic load, wiring situation, etc. *2 Lowest dischargeable voltage might be different depending on electronic load model to be connected, wiring situation, etc. *3 Ambient temperature at 18 °C to 28 °C *4 Common with 6 V/60 V ranges *5 Accuracy of transit times (termination condition) at charge/discharge time and at rest. *6 Corresponding to 30 seconds of monthly difference.