| Model | PLZ164W | PLZ334W | PLZ1004W | PLZ164WA | PLZ664WA | |
|---|---|---|---|---|---|---|
| Input voltage range | 100 VAC – 240 VAC (90 VAC – 250 VAC) Single phase, continuous | 100 VAC – 120 VAC/200 VAC – 240 VAC (90 VAC – 132 VAC/180 VAC – 250 VAC) Single phase | ||||
| Input frequency range | 47 Hz to 63 Hz | |||||
| Power | 80 VA max | 90 VAmax | 160 VAmax | 300 VAmax | 1500 VAmax *1 | |
| Inrush current | 45 A | 80 A | ||||
| Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | |||||
| Operating humidity range | 20 % – 85 % RH (without condensation) | |||||
| Storage temperature range | -25°C to 70°C (-13 °F to 158 °F) | |||||
| Storage humidity range | 90 % RH or less (without condensation) | |||||
| Isolation voltage | ± 500 V | |||||
| Insulation resistance | Between primary and input terminals | 500 VDC, 30 MΩ or more (ambient humidity of 70 % RH or less) | ||||
| Between primary and chassis | 500 VDC, 30 MΩ or more (ambient humidity of 70 % RH or less) | |||||
| Withstanding voltage | Between primary and input terminals | No abnormalities at 1500 VAC for 1 minute. | ||||
| Between primary and chassis | No abnormalities at 1500 VAC for 1 minute. | |||||
| Weight | Approx. 7 kg (15.43 lb) | Approx. 8 kg (17.64 lb) | Approx. 15 kg (33.1 lb.) | Approx. 7.5 kg (16.53 lb) | Approx. 16 kg (35.27 lb) | |
| Battery backup | Backs up setup information | |||||
| Accessories | Power cord × 1 pc. (with plug, Length: approx. 2.4 m), Load input terminal cover × 1 piece (2 lock plates provided), Set of screws for the load input terminal × 2 sets (bolts, nuts, and spring washers), Setup guide × 1 piece(Japanese, English), Quick Reference(Japanese:1 piece, Englis:1 piece), CD-ROM × 1 piece *2 | |||||
| Electromagnetic compatibility (EMC) *3, *4 | Conforms to the requirements of the following standard. EMC Directive 2014/30/EU EN 61326-1 (Class A *7), EN 55011 (Class A *7, Group 1 *8), EN 61000-3-2 *9 , EN 61000-3-3 *9 | |||||
| Safety *3 | Conforms to the requirements of the following standard. Low Voltage Directive 2014/35/EU *4 EN 61010-1 (Class I *5, Pollution degree 2 *6) | |||||
*1. 900 VA when input voltage is 100 VAC. *2. Contains Application & Samples, User’s manual, the Communication Interface Manual and KI-VISA. *3. Does not apply to specially ordered or modified PLZ-4Ws. *4. Limited to products that have the CE mark on their panels. Not be in compliance with EMC limits unless the ferritecore is attached on the cable for connection of J1 connector. *5. This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this productis only guaranteed when the product is properly grounded. *6. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength orsurface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasionaltemporary conductivity caused by condensation. *7. This is a Class A equipment. This product is intended for use in an industrial environment. This product may causeinterference if used in residential areas. Such use must be avoided unless the user takes special measures to reduceelectromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *8. This is a Group 1 equipment. This product does not generate and/ or use intentionally radio-frequency energy, in theform of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *9. Excluding the PLZ664WA.