There is no low leakage current (LLC) model in PWR-01 series.
The leakage currents for PWR-01 series are as follows under the following input conditions; however, these values are based on measurements and are for reference only.
Input: 100 Vac at 50 Hz
PWR401ML: 0.46 mA
PWR801ML: 0.73 mA
PWR1201ML: 1.4 mA
Input: 250 Vac at 60 Hz
PWR2001L: 0.5 mA